Norvi Logo
  • HOME
  • PRODUCTS
  • STORE
  • DOCUMENTATION
  • BLOG
  • CONTACT US
  • HOME
  • PRODUCTS
  • STORE
  • DOCUMENTATION
  • BLOG
  • CONTACT US

NORVI ESP32 HMI

  • ESP-HMI-5C-CI – DATASHEET
  • ESP-HMI-5C-VI – DATASHEET
  • ESP-HMI-5C-CI – USER GUIDE
  • ESP-HMI-5C-VI – USER GUIDE
  • GETTING STARTED WITH NORVI ESP32 HMI
  • LVGL EXAMPLE GUIDE FOR NORVI ESP32 HMI
  • SQUARELINE STUDIOS FOR NORVI ESP32 HMI GUI DESIGN
  • NORVI ESP32 HMI DISPLAY TOUCH CALIBRATION
  • NORVI HMI GUI DESIGN FOR I/O AND MODBUS

NORVI RASPBERRY PI HMI

  • RPI-PC-AM8-TO7 – DATASHEET
  • RPI-PC-AV8-TO7 – DATASHEET
  • USER MANUAL- RASPBERRY PI HMI
  • NODE-RED STARTUP GUIDE – RASPBERRY PI HMI
  • FLASHING OS FOR EMMC – RASPBERRY PI HMI

NORVI WITH MODBUS PROTOCOL

  • NORVI RS485 GPIO ALLOCATION TABLE
  • NORVI DEVICE AS A MODBUS RTU SLAVE
  • NORVI DEVICE AS A MODBUS RTU MASTER
  • MODBUS RTU COMMUNICATION THROUGH NORVI
  • NORVI HMI WITH MODBUS PROTOCOL
  • NORVI IIOT MODBUS TO MQTT GUIDE

NORVI IIOT-AE06-CS-M6

  • NORVI IIOT-AE06-CS-M6-HSE – TEST PROGRAM
  • NORVI IIOT-AE06-CS-M6-HSE- QSG

NORVI IIOT

  • NORVI IIOT-AE01-T
    • NORVI IIOT-AE01-T – Test Program
    • NORVI IIOT-AE01-T – Datasheet
    • NORVI IIOT-AE01-T – User Guide
  • NORVI IIOT-AE01-R
    • NORVI IIOT-AE01-R – Datasheet
    • NORVI IIOT-AE01-R – User Guide
    • NORVI IIOT-AE01-R – Test Program
  • NORVI IIOT-AE02-V
    • NORVI IIOT-AE02-V – Datasheet
    • NORVI IIOT-AE02-V – User Guide
    • NORVI IIOT-AE02-V – Test Program
  • NORVI IIOT-AE02-I
    • NORVI IIOT-AE02-I – Test Program
    • NORVI IIOT-AE02-I – Datasheet
    • NORVI IIOT-AE02-I – User Guide
  • NORVI IIOT-AE03
    • NORVI IIOT-AE03 – Test Program
    • NORVI IIOT-AE03 – Datasheet
    • NORVI IIOT-AE03 – User Guide
  • NORVI IIOT-AE04-I
    • NORVI IIOT-AE04-I – User Guide
    • NORVI IIOT-AE04-I – Test Program
    • NORVI IIOT-AE04-I – Datasheet
  • NORVI IIOT-AE04-V
    • NORVI IIOT-AE04-V – Datasheet
    • NORVI IIOT-AE04-V – User Guide
    • NORVI IIOT-AE04-V – Test Program

NORVI ENET

  • NORVI ENET-AE06-I
    • NORVI ENET-AE06-I – DATASHEET
    • NORVI ENET-AE06-I – USER GUIDE
    • NORVI ENET-AE06-I – TEST PROGRAM
  • NORVI ENET-AE06-V
    • NORVI ENET-AE06-V – DATASHEET
    • NORVI ENET-AE06-V – USER GUIDE
    • NORVI ENET-AE06-V – TEST PROGRAM
  • NORVI ENET-AE06-R
    • NORVI ENET-AE06-R – DATASHEET
    • NORVI ENET-AE06-R – USER GUIDE
    • NORVI ENET-AE06-R – TEST PROGRAM
  • NORVI ENET-AE06-T
    • NORVI ENET-AE06-T – DATASHEET
    • NORVI ENET-AE06-T – USER GUIDE
    • NORVI ENET-AE06-T – TEST PROGRAM

NORVI GSM 2G

  • NORVI GSM-AE02-I-G
    • NORVI GSM-AE02-I-G – DATASHEET
    • NORVI GSM-AE02-I-G- USER GUIDE
    • NORVI GSM-AE02-I-G TEST PROGRAM
  • NORVI GSM-AE02-V-G
    • NORVI GSM-AE02-V-G – DATASHEET
    • NORVI GSM-AE02-V-G – USER GUIDE
    • NORVI GSM-AE02-V-G – TEST PROGRAM
  • NORVI GSM-AE04-I-G
    • NORVI GSM-AE04-I-G – DATASHEET
    • NORVI GSM-AE04-I-G – USER GUIDE
    • NORVI GSM-AE04-I-G – TEST PROGRAM
  • NORVI GSM-AE04-V-G
    • NORVI GSM-AE04-V-G – DATASHEET
    • NORVI GSM-AE04-V-G – USER GUIDE
    • NORVI GSM-AE04-V-G – TEST PROGRAM
  • NORVI GSM-AE08-R-G
    • NORVI GSM-AE08-R-G – DATASHEET
    • NORVI GSM-AE08-R-G – USER GUIDE
    • NORVI GSM-AE08-R-G – TEST PROGRAM
  • NORVI GSM-AE07-R-G
    • NORVI GSM-AE07-R-G – DATASHEET
    • NORVI GSM-AE07-R-G – USER GUIDE
    • NORVI GSM-AE07-R-G – TEST PROGRAM
  • NORVI GSM-AE07-T-G
    • NORVI GSM-AE07-T-G – DATASHEET
    • NORVI GSM-AE07-T-G – USER GUIDE
    • NORVI GSM-AE07-T-G – TEST PROGRAM
  • NORVI GSM-AE08-I-G
    • NORVI GSM-AE08-I-G – Datasheet
    • NORVI GSM-AE08-I-G – USER GUIDE
    • NORVI GSM-AE08-I-G – TEST PROGRAM
  • NORVI GSM-AE08-T-G
    • NORVI GSM-AE08-T-G – DATASHEET
    • NORVI GSM-AE08-T-G – USER GUIDE
    • NORVI GSM-AE08-T-G – TEST PROGRAM
  • NORVI GSM-AE08-V-G
    • NORVI GSM-AE08-V-G – Datasheet
    • NORVI GSM-AE08-V-G – USER GUIDE
    • NORVI GSM-AE08-V-G – EST PROGRAM

NORVI GSM 4G LTE

  • NORVI GSM-AE02-V-L
    • NORVI GSM-AE02-V-L – DATASHEET
    • NORVI GSM-AE02-V-L – USER GUIDE
    • NORVI GSM-AE02-V-L – TEST PROGRAM
  • NORVI GSM-AE02-I-L
    • NORVI GSM-AE02-I-L – DATASHEET
    • NORVI GSM-AE02-I-L – USER GUIDE
    • NORVI GSM-AE02-I-L – TEST PROGRAM
  • NORVI GSM-AE04-I-L
    • NORVI GSM-AE04-I-L – DATASHEET
    • NORVI GSM-AE04-I-L – USER GUIDE
    • NORVI GSM-AE04-I-L – TEST PROGRAM
  • NORVI GSM-AE08-T-L
    • NORVI GSM-AE08-T-L – DATASHEET
    • NORVI GSM-AE08-T-L – USER GUIDE
    • NORVI GSM-AE08-T-L – TEST PROGRAM
  • NORVI GSM-AE07-R-L
    • NORVI GSM-AE07-R-L – DATASHEET
    • NORVI GSM-AE07-R-L – USER GUIDE
    • NORVI GSM-AE07-R-L – TEST PROGRAM
  • NORVI GSM-AE07-T-L
    • NORVI GSM-AE07-T-L – DATASHEET
    • NORVI GSM-AE07-T-L – USER GUIDE
    • NORVI GSM-AE07-T-L – TEST PROGRAM
  • NORVI GSM-AE08-V-L
    • NORVI GSM-AE08-V-L – DATASHEET
    • NORVI GSM-AE08-V-L – USER GUIDE
    • NORVI GSM-AE08-V-L – TEST PROGRAM
  • NORVI GSM-AE08-I-L
    • NORVI GSM-AE08-I-L – DATASHEET
    • NORVI GSM-AE08-I-L – USER GUIDE
    • NORVI GSM-AE08-I-L – TEST PROGRAM
  • NORVI GSM-AE08-R-L
    • NORVI GSM-AE08-R-L – DATASHEET
    • NORVI GSM-AE08-R-L – USER GUIDE
    • NORVI GSM-AE08-R-L – TEST PROGRAM
  • NORVI GSM-AE04-V-L
    • NORVI GSM-AE04-V-L – DATASHEET
    • NORVI GSM-AE04-V-L – USER GUIDE
    • NORVI GSM-AE04-V-L – TEST PROGRAM

NORVI AGENT1

  • NORVI AGENT 1-BT01-ES-SI
    • NORVI AGENT 1-BT01 – DATASHEET
    • NORVI AGENT 1-BT01 – TEST PROGRAM
    • NORVI AGENT 1-BT01 – USER GUIDE
  • NORVI AGENT 1-BT02-ES-SI
    • NORVI AGENT 1-BT02 – DATASHEET
    • NORVI AGENT 1-BT02 – TEST PROGRAM
    • NORVI AGENT 1-BT02 – USER GUIDE
  • NORVI AGENT 1-BT03-ES-SI
    • NORVI AGENT 1-BT03 – DATASHEET
    • NORVI AGENT 1-BT03 – TEST PROGRAM
    • NORVI AGENT 1-BT03 – USER GUIDE
  • NORVI AGENT 1-BT05-ES-SI
    • NORVI AGENT 1-BT05 – DATASHEET
    • NORVI AGENT 1-BT05 – TEST PROGRAM
    • NORVI AGENT 1-BT05 – USER GUIDE
  • NORVI AGENT 1-BM01-ES-SI
    • NORVI AGENT 1-BM01 – DATASHEET
    • NORVI AGENT 1-BM01 – USER GUIDE
    • NORVI AGENT 1-BM01 – TEST PROGRAM
  • NORVI AGENT 1-BT06-ES-SI
    • NORVI AGENT 1-BT06 – DATASHEET
    • NORVI AGENT 1-BT06 – TEST PROGRAM
    • NORVI AGENT 1-BT06 – USER GUIDE
  • NORVI AGENT 1-BM02-ES-SI
    • NORVI AGENT 1-BM02 – DATASHEET
    • NORVI AGENT 1-BM02 – TEST PROGRAM
    • NORVI AGENT 1-BM02 – USER GUIDE

NORVI AGENT1 LoRa

  • NORVI AGENT 1-BT05-ES-L
    • NORVI AGENT 1-BT05-ES-L – DATASHEET
    • NORVI AGENT 1-BT05-ES-L – USER GUIDE
    • NORVI AGENT 1-BT05-ES-L – TEST PROGRAM
  • NORVI AGENT 1-BM02-ES-L
    • NORVI AGENT 1-BM02-ES-L – DATASHEET
    • NORVI AGENT 1-BM02-ES-L – USER GUIDE
    • NORVI AGENT 1-BM02-ES-L – TEST PROGRAM
  • NORVI AGENT 1-BT02-ES-L
    • NORVI AGENT 1-BT02-ES-L – DATASHEET
    • NORVI AGENT 1-BT02-ES-L – USER GUIDE
    • NORVI AGENT 1-BT02-ES-L – TEST PROGRAM
  • NORVI AGENT 1-BT03-ES-L
    • NORVI AGENT 1-BT03-ES-L – DATASHEET
    • NORVI AGENT 1-BT03-ES-L – USER GUIDE
    • NORVI AGENT 1-BT03-ES-L – TEST PROGRAM
  • NORVI AGENT 1-BT06-ES-L
    • NORVI AGENT 1-BT06-ES-L – DATASHEET
    • NORVI AGENT 1-BT06-ES-L – USER GUIDE
    • NORVI AGENT 1-BT06-ES-L – TEST PROGRAM
  • NORVI AGENT 1-BM01-ES-L
    • NORVI AGENT 1-BM01-ES-L – DATASHEET
    • NORVI AGENT 1-BM01-ES-L – USER GUIDE
    • NORVI AGENT 1-BM01-ES-L – TEST PROGRAM
  • NORVI AGENT 1-BT01-ES-L
    • NORVI AGENT 1-BT01-ES-L – DATASHEET
    • NORVI AGENT 1-BT01-ES-L – USER GUIDE
    • NORVI AGENT 1-BT01-ES-L – TEST PROGRAM

NORVI AGENT1 NB-IoT

  • NORVI AGENT 1-BM01-ES-N
    • NORVI AGENT 1-BM01-ES-N – DATASHEET
    • NORVI AGENT 1-BM01-ES-N – USER GUIDE
    • NORVI AGENT 1-BM01-ES-N – TEST PROGRAM
  • NORVI AGENT 1-BM02-ES-N
    • NORVI AGENT 1-BM02-ES-N – DATASHEET
    • NORVI AGENT 1-BM02-ES-N – USER GUIDE
    • NORVI AGENT 1-BM02-ES-N – TEST PROGRAM
  • NORVI AGENT 1-BT02-ES-N
    • NORVI AGENT 1-BT02-ES-N – DATASHEET
    • NORVI AGENT 1-BT02-ES-N – USER GUIDE
    • NORVI AGENT 1-BT02-ES-N – TEST PROGRAM
  • NORVI AGENT 1-BT01-ES-N
    • NORVI AGENT 1-BT01-ES-N – DATASHEET
    • NORVI AGENT 1-BT01-ES-N – USER GUIDE
    • NORVI AGENT 1-BT01-ES-N – TEST PROGRAM
  • NORVI AGENT 1-BT03-ES-N
    • NORVI AGENT 1-BT03-ES-N – DATASHEET
    • NORVI AGENT 1-BT03-ES-N – USER GUIDE
    • NORVI AGENT 1-BT03-ES-N – TEST PROGRAM
  • NORVI AGENT 1-BT05-ES-N
    • NORVI AGENT 1-BT05-ES-N – DATASHEET
    • NORVI AGENT 1-BT05-ES-N – USER GUIDE
    • NORVI AGENT 1-BT05-ES-N – TEST PROGRAM
  • NORVI AGENT 1-BT06-ES-N
    • NORVI AGENT 1-BT06-ES-N – DATASHEET
    • NORVI AGENT 1-BT06-ES-N – USER GUIDE
    • NORVI AGENT 1-BT06-ES-N – TEST PROGRAM

NORVI AGENT1 4G LTE

  • NORVI AGENT 1-BT06-LTE
    • NORVI AGENT 1-BT06-LTE – DATASHEET
    • NORVI AGENT 1-BT06-LTE – USER GUIDE
    • NORVI AGENT 1-BT06-LTE – TEST PROGRAM
  • NORVI AGENT 1-BT05-LTE
    • NORVI AGENT 1-BT05-LTE – DATASHEET
    • NORVI AGENT 1-BT05-LTE – USER GUIDE
    • NORVI AGENT 1-BT05-LTE – TEST PROGRAM
  • NORVI AGENT 1-BT03-LTE
    • NORVI AGENT 1-BT03-LTE – DATASHEET
    • NORVI AGENT 1-BT03-LTE – USER GUIDE
    • NORVI AGENT 1-BT03-LTE – TEST PROGRAM
  • NORVI AGENT 1-BT02-LTE
    • NORVI AGENT 1-BT02-LTE – DATASHEET
    • NORVI AGENT 1-BT02-LTE – USER GUIDE
    • NORVI AGENT 1-BT02-LTE – TEST PROGRAM
  • NORVI AGENT 1-BT01-LTE
    • NORVI AGENT 1-BT01-LTE – DATASHEET
    • NORVI AGENT 1-BT01-LTE – USER GUIDE
    • NORVI AGENT 1-BT01-LTE – TEST PROGRAM
  • NORVI AGENT 1-BM01-LTE
    • NORVI AGENT 1-BM01-LTE – DATASHEET
    • NORVI AGENT 1-BM01-LTE – USER GUIDE
    • NORVI AGENT 1-BM01-LTE – TEST PROGRAM
  • NORVI AGENT 1-BM02-LTE
    • NORVI AGENT 1-BM02-LTE – DATASHEET
    • NORVI AGENT 1-BM02-LTE – USER GUIDE
    • NORVI AGENT 1-BM02-LTE – TEST PROGRAM

NORVI AGENT2

  • NORVI AGENT 2-AP01-BC1
    • NORVI AGENT 2-BC1 – DATASHEET
    • NORVI AGENT 2-BC1 – USER GUIDE
  • NORVI AGENT 2-AP01-BC2
    • NORVI AGENT 2-BC2 – DATASHEET
    • NORVI AGENT 2-BC2 – USER GUIDE
  • NORVI AGENT 2-AP01-BA1
    • NORVI AGENT 2-BA1 – DATASHEET
    • NORVI AGENT 2-BA1 – USER GUIDE
  • NORVI AGENT 2-AP01-BA2
    • NORVI AGENT 2-BA2 – DATASHEET
    • NORVI AGENT 2-BA2 – USER GUIDE

EC-M11-EG

  • EC-M11-EG-C1
    • EC-M11-EG-C1 – DATASHEET
    • EC-M11-EG-C1 – USER GUIDE
    • EC-M11-EG-C1 – TEST PROGRAM
  • EC-M11-EG-C2
    • EC-M11-EG-C2 – DATASHEET
    • EC-M11-EG-C2 – USER GUIDE
    • EC-M11-EG-C2 – TEST PROGRAM
  • EC-M11-EG-C3
    • EC-M11-EG-C3 – DATASHEET
    • EC-M11-EG-C3 – USER GUIDE
    • EC-M11-EG-C3 – TEST PROGRAM
  • EC-M11-EG-C4
    • EC-M11-EG-C4 – DATASHEET
    • EC-M11-EG-C4 – USER GUIDE
    • EC-M11-EG-C4 – TEST PROGRAM
  • EC-M11-EG-C5
    • EC-M11-EG-C5 – DATASHEET
    • EC-M11-EG-C5 – USER GUIDE
    • EC-M11-EG-C5 – TEST PROGRAM

EC-M11-EG 4G LTE

  • EC-M11-EG-C1-LTE
    • EC-M11-EG-C1-LTE – DATASHEET
    • EC-M11-EG-C1-LTE – USER GUIDE
    • EC-M11-EG-C1-LTE – TEST PROGRAM
  • EC-M11-EG-C2-LTE
    • EC-M11-EG-C2-LTE – DATASHEET
    • EC-M11-EG-C2-LTE – USER GUIDE
    • EC-M11-EG-C2-LTE – TEST PROGRAM
  • EC-M11-EG-C3-LTE
    • EC-M11-EG-C3-LTE – DATASHEET
    • EC-M11-EG-C3-LTE – USER GUIDE
    • EC-M11-EG-C3-LTE – TEST PROGRAM
  • EC-M11-EG-C4-LTE
    • EC-M11-EG-C4-LTE – DATASHEET
    • EC-M11-EG-C4-LTE – USER GUIDE
    • EC-M11-EG-C4-LTE – TEST PROGRAM
  • EC-M11-EG-C5-LTE
    • EC-M11-EG-C5-LTE – DATASHEET
    • EC-M11-EG-C5-LTE – USER GUIDE
    • EC-M11-EG-C5-LTE – TEST PROGRAM

EC-M11-EG NB-IoT

  • EC-M11-EG-C1-B95
    • EC-M11-EG-C1-B95 – DATASHEET
    • EC-M11-EG-C1-B95 – USER GUIDE
    • EC-M11-EG-C1-B95 – TEST PROGRAM
  • EC-M11-EG-C2-B95
    • EC-M11-EG-C2-B95 – DATASHEET
    • EC-M11-EG-C2-B95 – USER GUIDE
    • EC-M11-EG-C2-B95 – TEST PROGRAM
  • EC-M11-EG-C3-B95
    • EC-M11-EG-C3-B95 – DATASHEET
    • EC-M11-EG-C3-B95 – USER GUIDE
    • EC-M11-EG-C3-B95 – TEST PROGRAM
  • EC-M11-EG-C4-B95
    • EC-M11-EG-C4-B95 – DATASHEET
    • EC-M11-EG-C4-B95 – USER GUIDE
    • EC-M11-EG-C4-B95 – TEST PROGRAM
  • EC-M11-EG-C5-B95
    • EC-M11-EG-C5-B95 – DATASHEET
    • EC-M11-EG-C5-B95 – USER GUIDE
    • EC-M11-EG-C5-B95 – TEST PROGRAM

EC-M11-EG LoRa

  • EC-M11-EG-C4-S
    • EC-M11-EG-C4-S – DATASHEET
    • EC-M11-EG-C4-S – USER GUIDE
    • EC-M11-EG-C4-S – TEST PROGRAM
  • EC-M11-EG-C3-S
    • EC-M11-EG-C3-S – DATASHEET
    • EC-M11-EG-C3-S – USER GUIDE
    • EC-M11-EG-C3-S – TEST PROGRAM
  • EC-M11-EG-C2-S
    • EC-M11-EG-C2-S – DATASHEET
    • EC-M11-EG-C2-S – USER GUIDE
    • EC-M11-EG-C2-S – TEST PROGRAM
  • EC-M11-EG-C1-S
    • EC-M11-EG-C1-S – DATASHEET
    • EC-M11-EG-C1-S – USER GUIDE
    • EC-M11-EG-C1-S – TEST PROGRAM
  • EC-M11-EG-C5-S
    • EC-M11-EG-C5-S – DATASHEET
    • EC-M11-EG-C5-S – USER GUIDE
    • EC-M11-EG-C5-S – TEST PROGRAM

EC-M11-BC

  • EC-M11-BC-C1
    • EC-M11-BC-C1_V2 – DATASHEET
    • EC-M11-BC-C1 – USER GUIDE
    • EC-M11-BC-C1 – TEST PROGRAM
    • EC-M11-BC-C1 – DATASHEET
    • EC-M11-BC-C1_V2 – USER GUIDE
    • EC-M11-BC-C1_V2 – TEST PROGRAM
    • EC-M11-BC-C1_V3 – USER GUIDE
  • EC-M11-BC-C2
    • EC-M11-BC-C2 -DATASHEET
    • EC-M11-BC-C2 -USER GUIDE
    • EC-M11-BC-C2 – TEST PROGRAM
  • EC-M11-BC-C3
    • EC-M11-BC-C3 – DATASHEET
    • EC-M11-BC-C3 – USER GUIDE
    • EC-M11-BC-C3 – TEST PROGRAM
  • EC-M11-BC-C4
    • EC-M11-BC-C4 – DATASHEET
    • EC-M11-BC-C4 – USER GUIDE
    • EC-M11-BC-C4 – TEST PROGRAM

EC-M11-BC 4G LTE

  • EC-M11-BC-C1-LTE
    • EC-M11-BC-C1-LTE – DATASHEET
    • EC-M11-BC-C1-LTE – USER GUIDE
    • EC-M11-B-C1-LTE – TEST PROGRAM
    • EC-M11-BC-C1-LTE_V2 – DATASHEET
    • EC-M11-BC-C1-LTE_V2 – USER GUIDE
    • EC-M11-B-C1-LTE_V2 – TEST PROGRAM
    • EC-M11-BC-C1-LTE_V3 – USER GUIDE
  • EC-M11-BC-C2-LTE
    • EC-M11-BC-C2-LTE – DATASHEET
    • EC-M11-BC-C2-LTE – USER GUIDE
    • EC-M11-BC-C2-LTE – TEST PROGRAM
  • EC-M11-BC-C3-LTE
    • EC-M11-BC-C3-LTE – DATASHEET
    • EC-M11-BC-C3-LTE – USER GUIDE
    • EC-M11-BC-C3-LTE -TEST PROGRAM
  • EC-M11-BC-C4-LTE
    • EC-M11-BC-C4-LTE – DATASHEET
    • EC-M11-BC-C4-LTE – USER GUIDE
    • EC-M11-BC-C4-LTE – TEST PROGRAM

EC-M11-BC NB-IoT

  • EC-M11-BC-C1-B95
    • EC-M11-BC-C1-B95 – DATASHEET
    • EC-M11-BC-C1-B95 – USER GUIDE
    • EC-M11-BC-C1-B95 – TEST PROGRAM
    • EC-M11-BC-C1-B95_V2 – DATASHEET
    • EC-M11-BC-C1-B95_V2 – USER GUIDE
    • EC-M11-BC-C1-B95_V2 – TEST PROGRAM
    • EC-M11-BC-C1-B95_V3 – USER GUIDE
  • EC-M11-BC-C2-B95
    • EC-M11-BC-C2-B95 – DATASHEET
    • EC-M11-BC-C2-B95 – USER GUIDE
    • EC-M11-BC-C2-B95 – TEST PROGRAM
  • EC-M11-BC-C3-B95
    • EC-M11-BC-C3-B95 – DATASHEET
    • EC-M11-BC-C3-B95 – USER GUIDE
    • EC-M11-BC-C3-B95 – TEST PROGRAM
  • EC-M11-BC-C4-B95
    • EC-M11-BC-C4-B95 -DATASHEET
    • EC-M11-BC-C4-B95 -USER GUIDE
    • EC-M11-BC-C4-B95 -TEST PROGRAM

EC-M11-BC LoRa

  • EC-M11-BC-C4-S
    • EC-M11-BC-C4-S – DATASHEET
    • EC-M11-BC-C4-S – USER GUIDE
    • EC-M11-BC-C4-S – TEST PROGRAM
  • EC-M11-BC-C1-S
    • EC-M11-BC-C1-S – DATASHEET
    • EC-M11-BC-C1-S – USER GUIDE
    • EC-M11-BC-C1-S – TEST PROGRAM
    • EC-M11-BC-C1-S_V2 – USER GUIDE
    • EC-M11-BC-C1-S_V2 – DATASHEET
    • EC-M11-BC-C1-S_V2 – TEST PROGRAM
    • EC-M11-BC-C1-S_V3 – USER GUIDE
  • EC-M11-BC-C2-S
    • EC-M11-BC-C2-S – DATASHEET
    • EC-M11-BC-C2-S – USER GUIDE
    • EC-M11-BC-C2-S – TEST PROGRAM
  • EC-M11-BC-C3-S
    • EC-M11-BC-C3-S – DATASHEET
    • EC-M11-BC-C3-S – USER GUIDE
    • EC-M11-BC-C3-S – TEST PROGRAM

NORVI ANALOG EXPANSION

  • NORVI EX-ANV16
    • NORVI EX-ANV16 – DATASHEET
    • NORVI EX-ANV16 – USER GUIDE
    • NORVI EX-ANV16 – TEST PROGRAM
  • NORVI EX-ANQ 04
    • NORVI EX-ANQ 04 – DATASHEET
    • NORVI EX-ANQ 04 – USER GUIDE
    • NORVI EX-ANQ 04 – TEST PROGRAM
  • NORVI EX-ANV01
    • NORVI-EX-ANV01 – DATASHEET
    • NORVI-EX-ANV01 – USER GUIDE
    • NORVI EX-ANV01 – TEST PROGRAM
  • NORVI EX-ANI01
    • NORVI-EX-ANI01 – USER GUIDE
    • NORVI-EX-ANI01 – DATASHEET
    • NORVI EX-ANI01 – TEST PROGRAM

NORVI DIGITAL INPUT EXPANSION

  • NORVI EX-I4
    • NORVI-EX-I4 – DATASHEET
    • NORVI-EX-I4 – USER GUIDE
    • NORVI EX-I4 – TEST PROGRAM
  • NORVI EX-I8
    • NORVI-EX-I8 – DATASHEET
    • NORVI-EX-I8 – USER GUIDE
    • NORVI EX-I8 – TEST PROGRAM
  • NORVI EX-I16
    • NORVI-EX-I16 – DATASHEET
    • NORVI-EX-I16 – USER GUIDE
    • NORVI EX-I16 – TEST PROGRAM

NORVI TRANSISTOR OUTPUT EXPANSION

  • NORVI EX-Q4
    • NORVI-EX-Q4 – DATASHEET
    • NORVI-EX-Q4 – USER GUIDE
    • NORVI EX-Q4 – TEST PROGRAM
  • NORVI EX-Q8
    • NORVI-EX-Q8 – DATASHEET
    • NORVI-EX-Q8 – USER GUIDE
    • NORVI EX-Q8 – TEST PROGRAM
  • NORVI EX-Q16
    • NORVI-EX-Q16 – DATASHEET
    • NORVI-EX-Q16 – USER GUIDE
    • NORVI EX-Q16 – TEST PROGRAM

NORVI RELAY OUTPUT EXPANSION

  • NORVI EX-R8
    • NORVI-EX-R8 – DATASHEET
    • NORVI-EX-R8 – USER GUIDE
    • NORVI EX-R8 – TEST PROGRAM
  • NORVI EX-R16
    • NORVI-EX-R16 – DATASHEET
    • NORVI-EX-R16 – USER GUIDE
    • NORVI EX-R16 – TEST PROGRAM

NORVI CEMA

  • NORVI CEMA-M1
    • NORVI CEMA-M1 – DATASHEET
    • NORVI CEMA-M1 – USER GUIDE
    • NORVI CEMA-M1 – TEST PROGRAM
  • NORVI CEMA-M2
    • NORVI CEMA-M2 – DATASHEET
    • NORVI CEMA-M2 – USER GUIDE
    • NORVI CEMA-M2 – TEST PROGRAM

NORVI ARITA MEGA

  • NORVI ARITA-MEGA-M5
    • NORVI ARITA-MEGA-M5 – DATASHEET
    • NORVI ARITA-MEGA-M5 – USER GUIDE
    • NORVI ARITA-MEGA-M5 – TEST PROGRAM
  • NORVI ARITA-MEGA-M6
    • NORVI ARITA-MEGA-M6 – DATASHEET
    • NORVI ARITA-MEGA-M6 – USER GUIDE
    • NORVI ARITA-MEGA-M6 – TEST PROGRAM
  • NORVI ARITA-MEGA-M7
    • NORVI ARITA-MEGA-M7 – DATASHEET
    • NORVI ARITA-MEGA-M7 – USER GUIDE
    • NORVI ARITA-MEGA-M7 – TEST PROGRAM
  • NORVI ARITA-MEGA-M8
    • NORVI ARITA-MEGA-M8 – DATASHEET
    • NORVI ARITA-MEGA-M8 – USER GUIDE
    • NORVI ARITA-MEGA-M8 – TEST PROGRAM

NORVI ARITA STM32

  • NORVI ARITA-STM32-M5
    • NORVI ARITA-STM32-M5 – DATASHEET
    • NORVI ARITA-STM32-M5 – USER GUIDE
  • NORVI ARITA-STM32-M6
    • NORVI ARITA-STM32-M6 – DATASHEET
    • NORVI ARITA-STM32-M6 – USER GUIDE
  • NORVI ARITA-STM32-M7
    • NORVI ARITA-STM32-M7 – DATASHEET
    • NORVI ARITA-STM32-M7 – USER GUIDE
  • NORVI ARITA-STM32-M8
    • NORVI ARITA-STM32-M8 – DATASHEET
    • NORVI ARITA-STM32-M8 – USER GUIDE

NORVI WITH MQTT PROTOCOL

  • NORVI IIOT MQTT Guide
  • MQTT with QUECTEL EC25 Guide on NORVI GSM Series
  • Secure MQTT with QUECTEL EC25 Guide on NORVI GSM Series
  • MQTT with SIMCOM SIM7500 Guide on NORVI GSM Series
  • Secure MQTT with SIMCOM SIM7500 Guide on NORVI GSM Series

INDUSTRIAL CAMERA

  • NORVI AI OPTIC
    • NORVI AI OPTIC -DATASHEET
    • NORVI AI OPTIC – USER GUIDE
    • ESP32 S3 CAMERA OBJECT DETECTION GUIDE
    • ESP32 S3 CAMERA TFT DISPLAY INITIALIZATION AND GRAPHICS DEMO

NORVI EXPANSION

  • NORVI-EX-LRWAN
    • NORVI-EX-LRWAN-915 – DATASHEET
    • NORVI-EX-LRWAN-915 – USER GUIDE
    • NORVI EX-LRWAN-915 – TEST PROGRAM
  • NORVI EX-F16
    • NORVI EX-F16 – DATASHEET
    • NORVI EX-F16 – USER GUIDE
    • NORVI EX-F16 – TEST PROGRAM
  • NORVI EX-NB-IoT
    • NORVI EX-NB95G – DATASHEET
    • NORVI-EX-NB95G – USER GUIDE
    • NORVI EX-NB95G – TEST PROGRAM
  • NORVI EX-BR01
    • NORVI EX-BR01 – DATASHEET
    • NORVI-EX-BR01 – USER GUIDE
    • NORVI EX-BR01 – TEST PROGRAM
  • NORVI EX-TEX01
    • NORVI EX-TEX01 – DATASHEET
    • NORVI EX-TEX01 – TEST PROGRAM
  • NORVI EX-TEX02
    • NORVI EX-TEX02 – DATASHEET
  • NORVI-EX-LTE
    • NORVI EX-LTE – DATASHEET

OTA on ESP32

  • OTA UPDATES ON ESP32 WITH CELLULAR NETWORK
  • OTA UPDATES ON ESP32 OVER WIFI
View Categories
  • Home
  • Documentation
  • NORVI ANALOG EXPANSION
  • NORVI EX-ANV16
  • NORVI EX-ANV16 – DATASHEET

NORVI EX-ANV16 – DATASHEET

Product Features #

  • Up to Eight Differential Analog Inputs
  • Drive™ Technology  
  • Digitizes high Impedance Sensors
  • 0.02LSB Transition Noise
  • 50Hz/60Hz Rejection
  • 2ppm INL
  • 1ppm Offset and 15ppm Full-Scale Error
  • No Latency
  • DIN-Rail mount

Expansions Supported

  • Analog Input

Main #

Range of ProductNORVI Expansion
Product TypeExpansion Module
CertificationsEN 61131-2:2007
EN 61010-1:2010+A1:2019
EN IEC 61010-2-201:2018
2014/30/EU- Electromagnetic Compatibility (EMC)
Annex III, Part B, Module C 
Rated supply voltage24V DC
CommunicationI2C
Inputs and Outputs8 x 0 – 2.5V Differential Analog Inputs 
Displays and Visual IndicatorsLED green

Complementary #

Product Unified CodeNORVI-EX-ANV16
Product Part Numbers NORVI-EX-ANV16

Mechanical Properties #

EnclosureNORVI 204 
Mounting / Installation MethodDIN RAIL / MOUNTING TABS
Terminal TypeTop hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
Plate or panel with fixing kit
Terminal ArrangementTop and Bottom
Length90.50 mm
Height56.60 mm
Width60.60 mm

Environment #

IP degree of protection IP20
Operating altitude 0 – 2000 meters
Operating Temperature –10 … +85° C (14…185 °F)
Storage altitude 0 – 3000 meters
Shock resistance 15 gn for 11ms
Resistance to electrostatic discharge 4kV on contact 8kV on air
Resistance to electromagnetic fields 10 V/m (80 MHz …… 1GHz) 
3 V/m (1.4 MHz …… 2 GHz) 
1 V/m (2 MHz …… 3 GHz)

Electrical Characteristics #

Grid Powered Devices #

Rated Supply Voltage (V)  24V DC 
Current Consumption (mA)  400mA
Recommended Power Source  1A 24V DC

Processing #

ADC  TC2497CUHF#PBF
Module Type  16-bit, 8-Channel Differential ADC
Operating supply voltage  0 – 2.5V 
I2C SDA  EX Pin 10
I2C SCL  EX Pin 8

INPUTS and OUTPUTS #

Analog Inputs #

Number of Analog Inputs8
Analog Input Maximum Voltage6V
Analog to Digital Converter (ADC)LTC2497CUHF#PBF
Analog to Digital Converter (ADC) CommunicationI2C
Terminal Arrangement

I2C Address Assignment #

The LTC2497 has three address pins. Each may be tied high, low, or left floating enabling one of the possible addresses.

LTC2497 I2C Address AD2       AD1      AD0
0x14 Low Low Low 
0x15 Low Low Float
0x17Low FloatLow 
0x24 Low FloatFloat
0x35FloatLow Low 
0x36FloatLow Float
0x44 FloatFloatLow 
0x45FloatFloatFloat

I2C Address Setting #

The I2C address of the expansion module can be configured by switching DIP switches at the bottom of the expansion module. The device can be configured at 8 I2C addresses using the first 3 DIP switches.

Expansion Port #

The expansion port of the NORVI IIOT Controllers can be utilized for external sensor connections where raw GPIO connections are required or they can be used to plug NORVI Expansion Modules.  

PINESP32 Connection
1GPIO25
2TXD0
3AUX1
4RXD0
5NRST
6GPIO15
7AUX2
8SCL2
9GND
10SDA2
What are your Feelings
Share This Article :
  • Facebook
  • X
  • LinkedIn
  • Pinterest
Still stuck? How can we help?

How can we help?

Updated on August 2, 2024

Powered by BetterDocs

Table of Contents
  • Product Features
  • Main
  • Complementary
  • Mechanical Properties
  • Environment
  • Electrical Characteristics
    • Grid Powered Devices
  • Processing
  • INPUTS and OUTPUTS
    • Analog Inputs
    • I2C Address Assignment
    • I2C Address Setting
  • Expansion Port

Creating sustainable solutions that empower integrators, solution providers, and consumers.

Products

  • NORVI IIOT
  • NORVI ENET
  • NORVI GSM
  • NORVI AGENT 1
  • NORVI AGENT 2
  • Expansions
  • Solar Powered
  • Outdoor
  • NORVI HMI
  • RASPBERRY PI

Get Started

  • Documentation
  • Example Programs
  • Support

About

  • Blog
  • Stories
  • Community
  • Careers
  • Brand Assets

© 2018 All rights reserved

Twitter Facebook-f Youtube Medium